smartCUE Interfaces | User Manual | Factory Default
Factory Default
Conguration
Every device shipped from the factory is set according to this table.
Wired Models Wireless Models
Conguration Identication Name Empty Empty
Network IP address 192.168.1.254 192.168.1.254
Subnet mask 255.255.255.0 255.255.255.0
Default gateway 192.168.1.1 192.168.1.1
Admin Web port 80 80
TCP port 1 10001 10001
TCP port 2
(1)
10002 10002
UDP port 7777 7777
WiFi Network name (SSID) - smartCUE
Network type - Ad-Hoc
Channel (Ad-Hoc only) - 9
Security type - None
Encryption type - None
Security key - Empty
Password Empty (no input required) Empty (no input required)
(1)
Only for smartCUE-zero, smartCUE-zero-wifi, smartCUE-three, smartCUE-three-wifi
Restoring
The main purpose of this functionality is to regain connection with lost password or unknown IP settings.
To restore the factory default configuration, provide following steps
1. Turn the power off. Disconnect Ethernet cable for wired models or power adapter for wireless models.
2. Press button F.D. located on the front panel and hold it.
1 2
SERIAL
1 2 3 4
DIGITAL I/O
PWR
LINK
F. D.
Button factory default
3. Turn the power on and hold button F.D. at least 7 seconds.
4. Factory default configuration is restored according table above.