ipCUE Controllers
Version 04
Valid for XPL2 Firmware 4.0 and higher
CUE, a.s., K Nouzovu 6, 143 00 Praha 4, Czech Republic
phone: +420 241 091 240
fax: +420 241 432 446
www.cuesystem.com
Vista de página 0
1 2 3 4 5 6 ... 51 52

Resumo do Conteúdo

Página 1 - User Manual

User ManualipCUE ControllersVersion 04Valid for XPL2 Firmware 4.0 and higherCUE, a.s., K Nouzovu 6, 143 00 Praha 4, Czech Republicphone: +420 241 091

Página 2 - UM028_04, 1.10.2010

4.3. Windows Local Area Connection SettingsFor Windows 7 steps are1. Start Windows 7.2. Click Start.3. Enter ncpa.cpl to the Search Box and press Ente

Página 3 - Page 3 of 52

Following steps are4. Right-click on network adapter used for connection with ipCUE and then right-click and select Properties.5. Select Internet Prot

Página 4 - Page 4 of 52

5. Physical DescriptionThe ipCUE-alpha, ipCUE-beta, ipCUE-delta and ipCUE-epsilon front panels are made of aluminum plate. The ipCUE-gamma and ipCUE-s

Página 5 - 1. Introduction

5.4. ipCUE-delta5.5. ipCUE-epsilon5.6. ipCUE-sigmaUser Manual ipCUE Controllerswww.cuesystem.com Page 13 of 52

Página 6 - 2. Box Contents

6. Front Panel6.1. PWR IndicatorOff...No power presented.Blue On...Power 2

Página 7 - 3. Specifications

6.7. SERIAL Port IndicatorOff...No data transmitted or received through the serial port.Green On or Flashing

Página 8 - 4. Quick Start

7. Connection7.1. CUEnet (LAN)The CUEnet is a standard network connection 10/100 BaseT LAN using RJ-45 connector. There is no auto sense, which means

Página 9 - Using LAN Network

7.2. PWR INWarning: Use any ipCUE controller only with the power adapter supplied in the product package. Using another power supply may damage the un

Página 10 - Page 10 of 52

7.5. Bi-directional Serial RS-232Applicable for ipCUE-alpha, ipCUE-beta, ipCUE-gamma, ipCUE-delta, ipCUE-epsilon as SERIAL 1 - 2. Not applicable for i

Página 11 - 4.4. Access Admin Web Server

7.6. Bi-directional Serial RS-232/422/485OverviewThese bi-directional serial channels are used for RS-232, RS-422 and RS-485 communication. Maximum sp

Página 12 - 5. Physical Description

User Manual ipCUE ControllersUM028_04, 1.10.2010Copyright © CUE, a.s., Praha, Czech Republic 1990 - 2010All rights reserved. Specifications are subjec

Página 13 - 5.6. ipCUE-sigma

RS-422 ModeThis mode must be set in the programming application.Connector pin outRS-485 ModeThis mode must be set in the programming application.Conne

Página 14 - 6. Front Panel

7.7. Bi-directional Serial RS-232/422/485with Power 24 VDCOverviewThis bi-directional serial channel is used for RS-232, RS-422 and RS-485 communicati

Página 15 - Page 15 of 52

RS-422 ModeThis mode must be set in the programming application.Connector pin outRS-485 Mode (CUEwire)This mode is suitable for connection of CUEwire

Página 16 - 7. Connection

7.8. Bi-directional Serial RS-485with Power 24 VDC (CUEwire)This channel can be used as general RS-485 port or as CUEwire.This channel is applicable f

Página 17 - 7.4. OUT 12 V

7.9. IR/SERIALIR/Serial output is applicable as follows• IR/SERIAL 1 – 8 on ipCUE-alpha, ipCUE-beta, ipCUE-delta, ipCUE-epsilon• IR/SERIAL 1 – 3 on ip

Página 18 - Connector pin out

7.10. GENERAL I/OGeneral I/O provide analog input as well as digital output. Each General I/O port can be used either as input or as output.General I/

Página 19 - RS-232 Mode

7.11. DIGITAL I/ODigital I/O provide digital input as well as digital output. Each Digital I/O port can be used either as input or as output.Digital I

Página 20 - RS-485 Mode

7.12. ANALOGAnalog output provides analog output 0 - 10 V. When connecting with another device (e.g. dimmer) it is essential to see to a perfect inter

Página 21

7.13. RELAY (Low Voltage)This port provides one isolated low voltage relay. Normally Close and Normally Open contacts as well as Common contact of eac

Página 22 - RS-485 Mode (CUEwire)

7.14. RELAY (High Voltage)This port provides one isolated high voltage relay. Normally Close and Normally Open contacts as well as Common contact of e

Página 24 - 7.9. IR/SERIAL

8. CUEwire Device Connection8.1. CUEwire InstallationOn the picture you can see a typical connection of CUEwire.The cable consists of 4 wires. The fir

Página 25 - 7.10. GENERAL I/O

8.2. Simple CUEwire device connection8.3. Multiple CUEwire device connected to a CUEwire Splitter User Manual ipCUE Controllerswww.cuesystem.com Page

Página 26 - 7.11. DIGITAL I/O

9. Mounting9.1. Shelf Placement or StackingApplicable for ipCUE-alpha, ipCUE-beta, ipCUE-delta, ipCUE-epsilon and not applicable for ipCUE-gamma and i

Página 27 - 7.12. ANALOG

9.2. Rack MountingApplicable for ipCUE-alpha, ipCUE-beta, ipCUE-delta, ipCUE-epsilon and not applicable for ipCUE-gamma and ipCUE-sigma.The ipCUE Rack

Página 28 - 7.13. RELAY (Low Voltage)

9.3. DIN Rail MountingApplicable for ipCUE-gamma and ipCUE-sigma, not applicable for ipCUE-alpha, ipCUE-beta, ipCUE-delta, ipCUE-epsilon.ipCUE-gamma a

Página 29 - 7.14. RELAY (High Voltage)

10. Factory Default Settings and Reset / System Default ButtonEvery controller shipped from factory is set according to table bellow, Factory Default

Página 30 - 8. CUEwire Device Connection

11. Admin Web Server11.1. LoginYou have to login at first for operating with your ipCUE via these web pages.Enter your password into the Password box

Página 31 - Splitter

11.2. ConfigurationIdentificationEach ipCUE controller can be identified by a unique identification name. Unique names are most useful in applications

Página 32 - 9. Mounting

IP SettingsThis page is used for establishing the communication parameters for your ipCUE. The ipCUE uses standard internet protocol (IP) communicatio

Página 33 - 9.2. Rack Mounting

DNSThis page is used for setting parameters of your ipCUE’s DNS server. On start up, this page will display the ipCUE’s given Current primary DNS serv

Página 34 - 9.3. DIN Rail Mounting

10. Factory Default Settings and Reset / System Default Button

Página 35 - Reset / System Default Button

11.3. Date and TimeCurrent date and timeThis page is used for setting the time clock on your ipCUE. The current date, time, and time zone are shown on

Página 36 - 11. Admin Web Server

Internet clockThis page is used for synchronization of the ipCUE’s date and time with an internet clock. Begin by selecting the check box for Use Inte

Página 37 - 11.2. Configuration

11.4. ApplicationsThis page is used for uploading compiled CUE System Director® programs to your controller. All uploaded applications are listed on t

Página 38 - IP Settings

11.5. File StorageThe ipCUE’s generous memory can be used as an auxiliary file storage device. This is helpful for storing presets, in archiving elect

Página 39 - Page 39 of 52

11.6. E-mailThis page is used for setting parameters of email parameters and recipients addresses. The SMTP server must be set. See the Configuration/

Página 40 - 11.3. Date and Time

11.7. SystemFirmwareThis page is used for updating the ipCUE firmware. The Current version of firmware is shown. To upload new firmware, select the de

Página 41 - Internet clock

Format data areaTo completely clear all data and restore factory default settings, click the Format data area button. This will remove all data, inclu

Página 42 - 11.4. Applications

11.8. PasswordA case sensitive password is necessary to login to the web pages. Set a new password via the New password box. You must reenter the pass

Página 43 - 11.5. File Storage

11.9. BackupBackupThe page is used for the backup applications, files and folders. The Backup copies all Applications, Application data, File storage

Página 44 - 11.6. E-mail

RestoreREAD ALL IMPORTANT NOTES THAT FOLLOW BEFORE USING THIS OPERATION! The page is used for the restoring of all applications, files and folders. Re

Página 45 - 11.7. System

1. Introduction1.1. OverviewThe ipCUE are Ethernet IP enabled controllers. These controllers are well suited for single-room applications as well as h

Página 46 - Format data area

11.10. ResetTo restart your ipCUE, click the Reset button.11.11. LogoutWhen you are finished working with the ipCUE, click Logout to exit.User Manual

Página 47 - 11.8. Password

11.12. LicenseUser Manual ipCUE Controllerswww.cuesystem.com Page 51 of 52

Página 48 - 11.9. Backup

12. NotesUser Manual ipCUE Controllerswww.cuesystem.com Page 52 of 52

Página 49 - Page 49 of 52

2. Box ContentsItemipCUE-alphaipCUE-betaipCUE-gammaipCUE-deltaipCUE-epsilonipCUE-sigmaConnector Set1 set 1 set 1 set 1 set 1 set 1 setIR Adapter /i4 4

Página 50 - 11.11. Logout

3. Specifications FeatureipCUE-alphaipCUE-betaipCUE-gammaipCUE-deltaipCUE-epsilonipCUE-sigmaSystem connectionEthernet connection 10/100 BaseT LAN, RJ

Página 51 - 11.12. License

4. Quick Start4.1. Powering UpEvery ipCUE controller requires power from an external power supply. The standard CUEadapter /30W is delivered with the

Página 52 - 12. Notes

Notes1. 1000Base-T names are in parentheses.2. It's important that each pair is kept as a pair. TX+ & TX- must be in the pair and RX+ & R